The toque background trouble diagnosis table


TB-710, C-E-P TB-720, C-E-P TB-730, C-E-P

Symptom
A main cause
Coping
1
The neon lamp isn't turned on.
(AC100V)
An AC outlet is missing.
An AC fuse is cut off.
Neon lamp defect.
An AC outlet is put.
A fuse is replaced.
A neon lamp is replaced.
2
LED of DC24V doesn't stick.
Power supply trouble.
A DC fuse is cut off.
A power supply is replaced.
A fuse is replaced.
3
Only a part of the broadcasting system can't be used.
Circuit switch off or defect.
TB-2 trouble.
Child opportunity speaker trouble.
Or it is exchanged (circuit switch on).
TB-2 is exchanged.
A child opportunity speaker is replaced.
4
The whole circuit can't be broadcast.
General switch off or defect.
TB-MA trouble.
A general switch Better ‚­ exchanges on.
TB-MA is exchanged.

The toque background outline

Handling explanation

It is returned to the product guidance.